GPRM(1)                 COMMAND REFERENCE                 GPRM(1)



NAME
     gprm - remove GPIB instrument

     Not available for 4315, 4316 and 4317 UTek products.

SYNOPSIS
     gprm device...

DESCRIPTION
     gprm removes the specified GPIB device(s) from the
     configuration.  If device is an interface (gpibn), any
     attached instruments are removed first.

     If you physically remove a device from the bus by
     disconnecting its GPIB cable and and fail to use gprm, the
     workstation thinks the device is still on the bus.  When the
     workstation then goes out to service an SRQ, it will poll
     all the instruments it thinks are there and hang the program
     because the workstation can't read a status byte from the
     device that was removed.

EXAMPLES
     Remove the device ``fg5010'' from the configuration.

          $ gprm fg5010
          fg5010 removed

FILES
     /etc/gpibconf
                 Current configuration

     /etc/gpibnew
                 Temporary file

     /dev/gpibn  GPIB interface device

     /dev/gpidn  GPIB configuration device

     /dev/instrument
                 GPIB instruments

DIAGNOSTICS
     device removed
                 The named device has been removed from the
                 configuration.

     Other messages are system errors.  See intro(2) for more
     information on these.

RETURN VALUE
     [NO_ERRS]      Command completed without error.




Printed 4/6/89                                                  1





GPRM(1)                 COMMAND REFERENCE                 GPRM(1)



     [USAGE]        Incorrect command line syntax. Execution
                    terminated.

     [NP_WARN]      An error warranting a warning message
                    occurred. Execution continues.

     [NP_ERR]       An error occurred that was not a system
                    error.  Execution terminated.

     [P_WARN]       A system error occurred. Execution continues.
                    See intro(2) for more information on system
                    errors.

     [P_ERR]        A system error occurred. Execution
                    terminated.  See intro(2) for more
                    information on system errors.

SEE ALSO
     gpconf(1), gpinit(1), gpstat(1), gpib(4), gpid(4), gins(4)