INQUIRE NUMBER OF DISPLAY PRIORITIES SUPPORTED(3P)  —  SUNPHIGS LIBRARY

NAME

INQUIRE NUMBER OF DISPLAY PRIORITIES SUPPORTED − inquire number of display priorities supported by a workstation type

SYNOPSIS

C Syntax

void
pinqnumdisplaypri ( type, error_ind, num_pri )
Pwstypetype;workstation type
Pint∗error_ind;OUT error indicator
Pint∗num_pri;OUT number of display priorities

FORTRAN Syntax

SUBROUTINE pqdp ( WTYPE, ERRIND, NSPSUP )
INTEGERWTYPEworkstation type
INTEGERERRINDOUT error indicator
INTEGERNSPSUPOUT number of display priorities supported

Required PHIGS Operating States

(PHOP, ∗, ∗, ∗)

DESCRIPTION

Purpose

Use INQUIRE NUMBER OF DISPLAY PRIORITIES SUPPORTED to determine the number of display priorities supported by a specified workstation type. 

If the number of priorities returned is zero, this means the workstation type can support an arbitrary number of priorities. 

C Input Parameters

typeWorkstation type. 

C Output Parameters

error_ind
A pointer to the location to store the error number of any error detected by this function.

num_pri
Returns the number of display priorities supported on workstations of type type. 

FORTRAN Input Parameters

WTYPE
Workstation type.

FORTRAN Output Parameters

ERRIND
The error number of any error detected by this function.

NSPSUP
Returns the number of display priorities supported on workstations of type WTYPE. 

ERRORS

002Ignoring function, function requires state (PHOP, ∗, ∗, ∗)

051Ignoring function, this information is not yet available for this workstation type; open a workstation of this type and use the specific workstation type

052Ignoring function, workstation type not recognized by the implementation

059Ignoring function, the specified workstation does not have output capability (i.e., the workstation category is neither OUTPUT, OUTIN, nor MO)

062Ignoring function, this information is not available for this MO workstation type

SEE ALSO

POST STRUCTURE (3P)

Sun Release 4.0  —  Last change: 1 August 1989