ssaadm(1M)
NAME
ssaadm − administration program for SPARCstorage Array and SPARCstorage RSM disk systems
SYNOPSIS
ssaadm [ −v ] [ −e ] subcommand [ subcommand_option... ] | pathname...
DESCRIPTION
The ssaadm program is an administrative command that manages the SPARCstorage Array and SPARCstorage RSM disk systems (henceforth called SPARCstorage systems). ssaadm performs a variety of control and query tasks depending on the command line arguments and options used.
The command line must contain a subcommand (listed under USAGE) and at least one pathname. Commands specific to either a SPARCstorage Array or a SPARCstorage RSM will state that fact. It may also contain options and other parameters depending on the subcommand. The subcommand is applied to each of the pathnames on the command line.
pathname specifies the SPARCstorage system controller or a disk in the SPARCstorage system. The controller name is specified by its physical name, for example,
/devices/.../.../SUNW,soc@3,0/SUNW,pln@axxxxxxx,xxxxxxxx:ctlr
or by a name of the form
cN
where N is the logical controller number. ssaadm uses the cN name to find an entry in the /dev/rdsk directory of a disk that is attached to the SPARCstorage system controller. The /dev/rdsk entry is then used to determine the physical name of the SPARCstorage system controller. A disk in the SPARCstorage system is specified by its logical or physical device name, for example,
/dev/rdsk/c1t0d0s2
or
/devices/.../.../SUNW,soc@3,0/SUNW,pln@axxxxxxx,xxxxxxxx/ssd@0,0:c,raw
See disks(1M) for more information on logical names for disks and controllers.
OPTIONS
The following options are supported:
−v Verbose mode.
−e Expert mode. This is required for the expert mode subcommands listed below.
Subcommands and their options are described below. Expert mode subcommands are listed separately.
OPERANDS
The following operands are supported:
pathname The SPARCstorage system controller or a disk in the SPARCstorage system.
USAGE
Subcommands
display [−p] pathname...
Display configuration information for the specified unit(s) or display performance information for the specified SPARCstorage Array controller. If pathname specifies the controller, the configuration information is displayed for all disks in the SPARCstorage Array. For each drive that has fast write enabled, “(FW)” will be displayed after the drive identification.
−p Display performance information for the specified SPARCstorage Array controller. The accumulation of the performance statistics must be enabled using the perf_statistics subcommand before displaying the performance information. If not enabled, all of the I/Os per second will be displayed as zeros. The performance display reports the following information:
BUSY How busy the controller in the SPARCstorage Array is, expressed as a percentage.
IOPS The total I/Os per second for the SPARCstorage Array.
entries for each disk
The total number of I/Os per second.
download −f filename pathname
download −w wwn pathname
Download an image to the SPARCstorage Array controller.
−f Download the prom image specified by filename to the SPARCstorage Array controller FEPROMs. When the download is complete, the SPARCstorage Array must be reset in order to use the downloaded code. Note that the download subcommand modifies the FEPROM on the SPARCstorage Array and should be used with caution.
−w Change the SPARCstorage Array controller’s World Wide Name. wwn is a 12 digit hex number, leading zeros required. The new SPARCstorage Array controller’s image will have the least significant 6 bytes of the 8-byte World Wide Name modified to wwn.
fast_write [−s] −c pathname
fast_write [−s] −d pathname
fast_write [−s] −e pathname
Enable or disable the use of the NVRAM to enhance the performance of writes in the SPARCstorage Array. pathname may refer to the SPARCstorage Array controller or to an individual disk.
−s Save the state that is currently being requested so it will persist across power-cycles.
−c Enable fast writes for synchronous writes only.
−e Enable fast writes.
−d Disable fast writes.
fc_s_download [−f fcode-file]
Download the fcode contained in the file fcode-file into all the FC/S Sbus Cards. This command is interactive and expects user confirmation before downloading the fcode. When invoked without the [−f fcode-file] option, the current version of the fcode in each FC/S Sbus card is printed.
Note that the fc_s_download subcommand should be used only in single-user mode; otherwise the FC/S card could be reset.
insert_device pathname
Guide user through hot insertion of a disk device. See NOTES for hot plugging limitations.
perf_statistics −e pathname
perf_statistics −d pathname
Enable or disable the accumulation of performance statistics for the specified SPARCstorage Array controller. The accumulation of performance statistics must be enabled before using the display −p subcommand. This subcommand can be issued only to the SPARCstorage Array controller.
−e Enable the accumulation of performance statistics.
−d Disable the accumulation of performance statistics.
purge pathname
Purge any fast write data from NVRAM for one disk, or all disks if the controller is specified. This option should be used with caution, usually only when a drive has failed.
reserve pathname
Reserve the specified controller(s) or disk(s) for exclusive use by the issuing host. When HA (High_Availability) Software is running on a system, do not use this subcommand to reserve a disk on an SSA. Doing so could cause problems for the HA software.
release pathname
Release a reservation held on the specified controller(s) or disk(s). When HA (High_Availability) Software is running on a system, do not use this subcommand to release a disk on an SSA. Doing so could cause problems for the HA software.
remove_device pathname
Guide user through hot removal of a disk device. See NOTES for hot plugging limitations.
replace_device pathname
Guide user through hot replacement of a disk device. See NOTES for hot plugging limitations.
set_boot_dev [−y] pathname
Set the boot-device variable in the PROM to the physical device name specified by pathname which can be a block special device or a mount-point. The command normally runs interactively and requests confirmation for setting the default boot-device in the PROM. The −y option can be used to run it in non-interactive mode, in which case no confirmation is requested or required.
start [−t tray-number] pathname
Spin up the specified disk(s). If pathname specifies the controller, this action applies to all disks in the SPARCstorage Array.
−t Spin up all disks in the tray specified by tray-number. pathname must specify the controller.
stop [−t tray-number] pathname
Spin down the specified disk(s). If pathname specifies the controller, this action applies to all disks in the SPARCstorage Array.
−t Spin down all disks in the tray specified by tray-number. pathname must specify the controller.
sync_cache pathname
Flush all outstanding writes for the specified disk from NVRAM to the media. If pathname specifies the controller, this action applies to all disks in the SPARCstorage Array.
SCSI Enclosure
Services (SES)
Commands
The SPARCstorage RSM tray is addressed by the using the logical or physical path of the SES device or specifying the controller followed by the tray number if that controller has multiple trays. The controller is addressed by cN or the physical path to the SPARCstorage Array’s controller.
See ses(7D) for more information about environmental sensor cards and associated devices.
These commands also work with RSM trays directly attached to wide differential SCSI controllers.
env_display pathname | controller tray-number
Display the environmental information for the specified unit.
alarm pathname | controller tray-number
Display the current state of the audible alarm.
alarm_on pathname | controller tray-number
alarm_off pathname | controller tray-number
Enable or disable the audible alarm for this enclosure.
alarm_set pathname | controller tray-number [seconds]
Set the audible alarm setting to seconds.
led pathname
Display the current state of the led for the specified disk.
led_on pathname
led_off pathname
Turn on or off the led for this disk.
power_off pathname | controller tray-number
Power down this RSM. The RSM will need to be powered back on manually. This command does not work with RSMs directly attached to wide differential SCSI controllers.
Expert Mode Subcommands
See NOTES for limitations of these subcommands. Only users that are knowledgeable about the systems they are managing should use the expert mode subcommands.
For the following subcommands that work on a bus if a disk is specified then the bus that disk attached to is used.
bus_getstate pathname
Get and display the state of the specified bus.
bus_quiesce pathname
Quiesce the specified bus.
bus_reset pathname
Reset the specified bus.
bus_resetall pathname
Reset the specified bus and all devices on that bus.
bus_unquiesce pathname
Unquiesce the specified bus.
dev_getstate pathname
Get the state (online or offline) of the specified device.
dev_reset pathname
Reset the specified device.
offline pathname
Turn the specified disk offline.
online pathname
Turn the specified disk online.
EXAMPLES
An example of using the expert mode hot plugging subcommands to hot remove a disk on a SSA follows. See NOTES for hot plugging limitations.
The first step reserves the SCSI device so that it can’t be accessed via its second SCSI bus:
example# ssaadm reserve /dev/dsk/c1t8d0s2
The next two steps take the disk to be removed offline then quiesce the bus:
example# ssaadm −e offline /dev/dsk/c1t8d0s2
example# ssaadm −e bus_quiesce /dev/dsk/c1t8d0s2
The user then removes the disk and continues by unquiescing the bus, putting the disk back online, then releasing it:
example# ssaadm −e bus_unquiesce /dev/dsk/c1t8d0s2
example# ssaadm −e online /dev/dsk/c1t8d0s2
example# ssaadm release /dev/dsk/c1t8d0s2
EXIT STATUS
The following exit values are returned:
0 Successful completion.
non-zero An error occurred.
ATTRIBUTES
See attributes(5) for descriptions of the following attributes:
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
| Availability | SUNWssaop |
SEE ALSO
disks(1M), luxadm(1M), attributes(5), ses(7D)
SPARCstorage Array User’s Guide
Product Notes: Sun RSM Array 2000 Software
NOTES
Currently, only some device drivers support hot plugging. If hot plugging is attempted on a disk or bus where it is not supported, an error message of the form:
ssaadm: can’t acquire "PATHNAME": No such file or directory
will be displayed.
The non-expert mode hot plugging subcommands insert_device, remove_device and replace_device are currently only supported for the RSM SPARCstorage platform. See EXAMPLES for how to use the expert mode subcommands to hot plug on any platform that supports it.
Do not quiesce any bus containing a disk with the root, usr, or swap partitions to avoid possible system deadlock.
SunOS 5.6 — Last change: 19 Jun 1997