NAME

prtdiag − display system diagnostic information

SYNOPSIS

/usr/platform/platform-name/sbin/prtdiag [ −v ] [ −l ]

DESCRIPTION

prtdiag displays system configuration and diagnostic information. 

The diagnostic information lists any failed Field Replaceable Units (FRUs) in the system. 

The interface, output, and location in the directory hierarchy for prtdiag are uncommitted and subject to change in future releases. 

platform-name is the name of the platform implementation and can be found using the −i option of uname(1). 

OPTIONS

The following options are supported:

−v Verbose mode.  Displays the time of the most recent AC Power failure, and the most recent hardware fatal error information, and (if applicable) environmental status.  The hardware fatal error information is useful to repair and manufacturing for detailed diagnostics of FRUs. 

−l Log output.  If failures or errors exist in the system, output this information to syslogd(1M) only. 

EXIT STATUS

The following exit values are returned:

0 No failures or errors are detected in the system. 

1 Failures or errors are detected in the system. 

ATTRIBUTES

See attributes(5) for descriptions of the following attributes:

ATTRIBUTE TYPE ATTRIBUTE VALUE
Availability SUNWkvm

SEE ALSO

uname(1), modinfo(1M), prtconf(1M), psrinfo(1M), sysdef(1M), syslogd(1M), attributes(5), openprom(7D)