ALARM(2)  —  Silicon Graphics

NAME

alarm − set a process’s alarm clock

SYNOPSIS

unsigned alarm (sec)
unsigned sec;

DESCRIPTION

Alarm instructs the calling process’s alarm clock to send the signal SIGALRM to the calling process after the number of real time seconds specified by sec have elapsed; see signal(2).

Alarm requests are not stacked; successive calls reset the calling process’s alarm clock.  If the argument is 0, any alarm request is canceled.  Because the clock has a 1-second resolution, the signal may occur up to one second early; because of scheduling delays, resumption of execution of when the signal is caught may be delayed an arbitrary amount.  The longest specifiable delay time is 4,294,967,295 (2**32-1) seconds, or 136 years. 

If sec is 0, any previously made alarm request is canceled. 

RETURN VALUE

Alarm returns the amount of time previously remaining in the calling process’s alarm clock. 

SEE ALSO

pause(2), signal(2). 

ASSEMBLER

moveq#27,D0
movlsec,A0
trap#0

On return, D0 will contain the amount of time previously remaining in the alarm clock. 

Version 2.5r1  —  October 29, 1986