  ALARM(2)                                                 ALARM(2)



  NAME
       alarm - set a process alarm clock

  SYNOPSIS
       unsigned alarm (sec)
       unsigned sec;

  DESCRIPTION
       alarm instructs the alarm clock of the calling process to
       send the signal SIGALRM to the calling process after the
       number of real time seconds specified by sec have elapsed
       [see signal(2)].

       Alarm requests are not stacked; successive calls reset the
       alarm clock of the calling process.

       If sec is 0, any previously made alarm request is canceled.

  SEE ALSO
       pause(2), signal(2), sigpause(2), sigset(2).

  DIAGNOSTICS
       alarm returns the amount of time previously remaining in the
       alarm clock of the calling process.