NAME

hpib_card_ppoll_resp − control response to parallel poll on HP-IB

SYNOPSIS

int hpib_card_ppoll_resp (eid,flag);
int eid,flag;

DESCRIPTION

Hpib_card_ppoll_resp  enables  an  interface  to  enable  (or disable) itself for parallel polls.  It also controls the sense, and determines the line on which the response is sent.  This gives the  interface the  ability to either ignore or respond to a  parallel  poll  depending  upon  whether  or  not it is enabled to respond. 

Eid is an entity identifier of an open HP-IB raw bus device file obtained from an open(2), dup(2), fcntl(2), or creat(2) call.  Flag is an integer having one of the following bit patterns:

Bit Pattern Meaning

   10000 Disable parallel poll response. 

   0SPPP Enable parallel poll response, where

S = sense of the response, and
PPP = 3-bit binary number specifying the line on which the response is sent (0 − 7 octal).

RETURN VALUE

Hpib_card_ppoll_resp returns 0 (zero) if  successful,  or −1 if an error was encountered. 

ERRORS

Hpib_card_ppoll_resp fails under the following circumstances, and sets errno (see errno(2)) to the value in square brackets:

­[EBADF] eid does not refer to an open file. 

­[ENOTTY] eid does not refer to an HP-IB raw bus device file. 

­[EINVAL] the device cannot respond on the line number specified by flag. 

DEPENDENCIES

Series 300
The HP 98625A/B HP-IB interface supports only enabling and disabling the parallel poll response (bit 4 of flag).  The sense and response line number are not programmable on this card. 

Series 500
Note that the HP 27110A HP-IB interface supports only enabling and disabling the parallel poll response (bit 4 of flag).  The sense and response line number are not programmable on this card. 

Series 800
Since the sense and response line number are not programmable on the HP27110B HP-IB interface, the equivalent parallel poll configuration commands are sent over the HP-IB to the interface.  Therefore, this function will fail if the interface is not active controller.

AUTHOR

Hpib_card_ppoll_resp was developed by HP. 

SEE ALSO

hpib_ppoll(3I), hpib_ppoll_resp_ctl(3I). 

Hewlett-Packard Company  —  Version B.1,  May 11, 2021