cied(7) DG/UX 4.30 cied(7)
NAME
cied - AViiON family disk subsystem
DESCRIPTION
A cied disk subsystem consists of a VME-based disk
controller with up to 4 physical ESDI (Enhanced Small Device
Interface) units on that controller. The units supported are
as follows:
Model # Size
6442 327 Mbyte full-height non-removable disk
6661 327 Mbyte half-height non-removable disk
6555 648 Mbyte full-height non-removable disk
A physical disk unit may be accessed directly via the
special file nodes in /dev/pdsk and /dev/rpdsk. These nodes
are named in the form:
/dev/[r]pdsk/cied@<n>(<addr>,<m>)
where <n> is the hexadecimal device code of the controller,
<addr> is the control space starting address for the
controller, and <m> is the unit on the controller. The
nodes in /dev/pdsk provide access as a block special device
as described in dsk(7). The nodes in /dev/rpdsk provide
access as a character special device as described in
rdsk(7). When accessing a disk through a /dev/pdsk or
/dev/rpdsk node, the operating system performs no bad block
remapping.
FILES
/dev/pdsk/*
/dev/rpdsk/*
SEE ALSO
cird(7), dsk(7), rdsk(7).
Licensed material--property of copyright holder(s) Page 1