PSWKV(3g)  —  Subroutines

Name

PSWKV − Resets the workstation transformation according to 2D viewport limits. 

Operating States: PHOP, WSOP, ∗, ∗
PHIGS standard function
 

Syntax

PSWKV (WKID, XMIN, XMAX, YMIN, YMAX)

Argument       Data Type      Access    Description
---------------------------------------------------------------------------
WKID           Integer        Read      Workstation identifier
XMIN, XMAX,    Real           Read      Workstation viewport limits, in
YMIN, YMAX                              device coordinates
---------------------------------------------------------------------------

Description

PSWKV resets the workstation transformation on the specified workstation. (See Getting Started with DEC PHIGS for information about workstation transformations and the coordinate systems comprising the transformation pipeline.) 

You specify two-dimensional viewport limits within device coordinate space in the order XMIN, XMAX, YMIN, YMAX.  The XMIN and YMIN values must be less than the XMAX and YMAX values, respectively.  Digital PHIGS sets the ZMIN value to 0 and sets the ZMAX value to the maximum display space size in z. 

The PSWKV function sets the x and y components of the requested workstation viewport entry in the workstation state list to the specified values.  Initially, only the requested entry is set, because workstation transformation may be deferred.  (See the PUWK function.) 

When Digital PHIGS updates the workstation, it resets the current workstation viewport entry in the workstation state list as influenced by the values of these entries:

•The dynamic modification accepted (DMA) for workstation transformation entry in the workstation description table (where IMM indicates that all picture changes of the specified category can be performed immediately)

•The display space empty (DSE) entry in the workstation state list

•The workstation transformation update state entry in the workstation state list

The effects are defined in the following table:

DMA    DSE    Result
------------------------------------------------------------------------
IMM    N/A    The current workstation viewport entry is set to the
              specified value, and the workstation transformation
              update state entry is set to NOTPENDING.
N/A    EMPTY  The current workstation viewport entry is set to the
              specified value, and the workstation transformation
              update state entry is set to NOTPENDING.
Not    Not    The current workstation viewport entry is unchanged,
IMM    EMPTY  and the workstation transformation update state entry
              is set to PENDING.
------------------------------------------------------------------------

The z-components of the requested and current workstation window entries remain unchanged. 

The workstation transformation is an isotropic transformation.  Therefore, if the workstation window and the workstation viewport do not have the same aspect ratio, the workstation viewport is not fully utilized. 

The default workstation viewport is the maximum display space of the workstation. 