PSWKV(3g) — Subroutines
Name
PSWKV − Resets the workstation transformation according to 2D viewport limits.
Operating States: PHOP, WSOP, ∗, ∗
PHIGS standard function
Syntax
PSWKV (WKID, XMIN, XMAX, YMIN, YMAX)
Argument Data Type Access Description
---------------------------------------------------------------------------
WKID Integer Read Workstation identifier
XMIN, XMAX, Real Read Workstation viewport limits, in
YMIN, YMAX device coordinates
---------------------------------------------------------------------------
Description
PSWKV resets the workstation transformation on the specified workstation. (See Getting Started with DEC PHIGS for information about workstation transformations and the coordinate systems comprising the transformation pipeline.)
You specify two-dimensional viewport limits within device coordinate space in the order XMIN, XMAX, YMIN, YMAX. The XMIN and YMIN values must be less than the XMAX and YMAX values, respectively. Digital PHIGS sets the ZMIN value to 0 and sets the ZMAX value to the maximum display space size in z.
The PSWKV function sets the x and y components of the requested workstation viewport entry in the workstation state list to the specified values. Initially, only the requested entry is set, because workstation transformation may be deferred. (See the PUWK function.)
When Digital PHIGS updates the workstation, it resets the current workstation viewport entry in the workstation state list as influenced by the values of these entries:
•The dynamic modification accepted (DMA) for workstation transformation entry in the workstation description table (where IMM indicates that all picture changes of the specified category can be performed immediately)
•The display space empty (DSE) entry in the workstation state list
•The workstation transformation update state entry in the workstation state list
The effects are defined in the following table:
DMA DSE Result
------------------------------------------------------------------------
IMM N/A The current workstation viewport entry is set to the
specified value, and the workstation transformation
update state entry is set to NOTPENDING.
N/A EMPTY The current workstation viewport entry is set to the
specified value, and the workstation transformation
update state entry is set to NOTPENDING.
Not Not The current workstation viewport entry is unchanged,
IMM EMPTY and the workstation transformation update state entry
is set to PENDING.
------------------------------------------------------------------------
The z-components of the requested and current workstation window entries remain unchanged.
The workstation transformation is an isotropic transformation. Therefore, if the workstation window and the workstation viewport do not have the same aspect ratio, the workstation viewport is not fully utilized.
The default workstation viewport is the maximum display space of the workstation.
See Also
PQDSP
PQWKT
PSWKV3
PSWKW
PUWK