PSMCH(3g)  —  Subroutines

Name

PSMCH − Returns the choice number from the choice-class logical input device specified. 

Operating States: PHOP, WSOP, ∗, ∗
PHIGS standard function
 

Syntax

PSMCH (WKID, CHDNR, STAT, CHNR)

Argument        Data Type      Access   Description
---------------------------------------------------------------------------
WKID            Integer        Read     Workstation identifier
CHDNR           Integer        Read     Choice device number
STAT            Integer        Write    Status
CHNR            Integer        Write    Choice number
---------------------------------------------------------------------------

Constants

Defined Argument     Constant       Description
---------------------------------------------------------------------------
STAT                 POK            Measure contains a choice.
                     PNCHOI         Measure does not contain a choice.
---------------------------------------------------------------------------

Description

PSMCH takes the current measure of the choice-class logical input device specified by the device number and the workstation identifier.  If the input status is POK, this function returns your choice number (a positive integer). 