VAXTPU SET(RECORD_ATTRIBUTE) — VMS 5.5

 SET(RECORD_ATTRIBUTE)

    Sets or alters any of three possible attributes for the specified
    record or records.  The attributes you can set for a record are its
    left margin, its modifiability, and its visibility.

 Syntax

    SET (RECORD_ATTRIBUTE, {mark | range | buffer},
                           {DISPLAY_VALUE | LEFT_MARGIN},
                           {display_setting_integer | margin_setting_integer})

                                       or

    SET (RECORD_ATTRIBUTE, [marker | range | buffer], MODIFIABLE, [ON | OFF])


 Parameters

     RECORD_ATTRIBUTE         A keyword indicating that the SET built-in is
                              being used to specify or change a record
                              attribute.

     marker                   The marker marking the the record whose
                              attribute you want to set.

     range                    The range containing the records whose
                              attribute you want to set.

     buffer                   The buffer containing the records for which
                              you want to set an attribute.  When you
                              specify a buffer for the second parameter,
                              the record attribute is applied to all
                              records in the buffer.

     DISPLAY_VALUE            A keyword indicating that you want to affect
                              the visibility of the record.  If you specify
                              the DISPLAY_VALUE keyword as the third
                              parameter, you must specify for the fourth
                              parameter an integer providing a display
                              setting.

     LEFT_MARGIN              A keyword indicating that you want to specify
                              the left margin for the specified records.
                              If you specify the LEFT_MARGIN keyword as the
                              third parameter, you must specify for the
                              fourth parameter an integer providing a left
                              margin value.

     display_setting_integer  An integer value from -127 to +127.  This is
                              the display setting.  To determine whether a
                              record is to be visible or invisible in a
                              given window, VAXTPU compares the record's
                              display setting to the window's display
                              setting.  (A window's display setting is
                              specified with SET (DISPLAY_VALUE).) If the
                              record's setting is greater than or equal to
                              the window's setting, VAXTPU makes the record
                              visible in that window; otherwise, VAXTPU
                              makes the record invisible.

     margin_setting_integer   An integer that is the column in which the
                              left margin should be set.  The value must be
                              between 1 and the value of the right margin.
                              (The maximum valid value for the right margin
                              is 960.)

     MODIFIABLE               A keyword indicating that you want to
                              determine whether the specified records are
                              modifiable.  If you specify the MODIFIABLE
                              keyword as the third parameter, you must
                              specify either ON or OFF as the fourth
                              parameter.

     ON                       A keyword making records modifiable.  Note,
                              if a buffer has been set as unmodifiable
                              using SET (MODIFIABLE), you cannot make a
                              record in that buffer modifiable using SET
                              (RECORD_ATTRIBUTE).  If the buffer is
                              modifiable, however, you can use SET
                              (RECORD_ATTRIBUTE) to make a record
                              unmodifiable.

     OFF                      A keyword making records unmodifiable.

 Comments

    You can set only one attribute with each call to SET
    (RECORD_ATTRIBUTE).  For example, you cannot change visibility and
    modifiability using just one call.  To set more than one record
    attribute, use multiple calls to SET (RECORD_ATTRIBUTE).

    When you set an attribute for multiple records, each record gets the
    same value.  For example, if you specify a range of records and a value
    for the left margin attribute, all records in the range receive the
    same left margin value.

    You cannot change the left margin of an unmodifiable record.  You can
    change the display value of a record at any time.  You can change the
    modifiability of a record if the buffer is modifiable.

 Examples


    1.  The following statement sets the left margin of all records in the
        current buffer to column 3:

        SET (RECORD_ATTRIBUTE, CURRENT_BUFFER, LEFT_MARGIN, 3);


    2.  The following statements make the records in the range
        "select_range" invisible in the current window:

        SET (DISPLAY_VALUE, CURRENT_WINDOW, 0);
        SET (RECORD_ATTRIBUTE, select_range, -1);


    3.  The following statement makes the current record unmodifiable:

        SET (RECORD_ATTRIBUTE, MARK (FREE_CURSOR), MODIFIABLE, OFF);



 Related Topics

    GET_INFO(BUFFER_VARIABLE)          GET_INFO(MARKER_VARIABLE)
    GET_INFO(WINDOW_VARIABLE)          SET(DISPLAY_VALUE)
    SET(ERASE_UNMODIFIABLE)            SET(LEFT_MARGIN)
    SET(MODIFIABLE)