SHOW CLUSTER — VMS 5.5-2H4
Additional information available:
ADDDEFAULT_KEYPADDEFINEDESELECTEXITHELP
INITIALIZEMOVEPANREFRESHREMOVESAVESCROLL
SELECTSETWRITE
Changes
New Commands
--------------
REMOVE SYSTEMS /ID = ALL
ADD SYSTEMS /ID = ALL
REMOVE SYSTEMS /NODE = ALL
ADD SYSTEMS /NODE = ALL
ADD CONNECTIONS /NAME = loc-proc-name
ADD CONNECTIONS /NAME = ALL
REMOVE CONNECTIONS /NAME = loc-proc-name
REMOVE CONNECTIONS /NAME = ALL
New Fields
------------
CL_EXPECTED_VOTES
CL_MEMBERS
EXPECTED_VOTES
RECNXINTERVAL
SW_VERS
New Features
--------------
New format for data in HW_TYPE field.
A single window can be SCROLLed without being selected.
A single window will automatically be selected and
AUTO_POSITIONING turned off when a MOVE command is entered.
A Show Cluster command can be entered while Help text is
still on the screen.
Classes
The classes available for display are: CLUSTER SYSTEMS MEMBERS CIRCUITS CONNECTIONS COUNTERS CREDITS LOCAL_PORTS ERRORS
Additional information available:
CLUSTERSYSTEMSMEMBERSCIRCUITSCONNECTIONSCOUNTERS
CREDITSLOCAL_PORTSERRORS
CLUSTER
The cluster class contains general information about the cluster. This class includes information such as the time the cluster was formed, the time of the last transition, and the cluster quorum.
Additional information available:
CL_EXPECTED_VOTESCL_MEMBERSCL_QDVOTES
CL_QUORUMCL_VOTESFORMEDLAST_TRANSITIONMEMSEQ
QD_NAMEQF_VOTE
CL_EXPECTED_VOTES
The CL_EXPECTED_VOTES field displays the number of votes expected to be contributed by all members of the cluster as determined by the connection manager. This value is based on the maximum of EXPECTED_VOTES and the maximized value of CL_VOTES.
CL_MEMBERS
The CL_MEMBERS field displays the number of systems which are currently members of the cluster.
CL_QDVOTES
The CL_QDVOTES field displays the number of quorum votes currently being contributed by the quorum disk.
CL_QUORUM
The CL_QUORUM field displays the number of votes required for the cluster to have quorum.
CL_VOTES
THE CL_VOTES field displays the total number of quorum votes currently being contributed by all cluster members and the quorum disk.
FORMED
The time at which the cluster was formed. (DD-MMM-YY HH:MM).
LAST_TRANSITION
The LAST_TRANSITION time is the time at which a system last left or joined the cluster. (DD-MMM-YY HH:MM)
MEMSEQ
The MEMSEQ field displays the membership state sequence number.
QD_NAME
The full device name of the quorum disk.
QF_VOTE
The QF_VOTE field indicates whether or not the quorum disk is contributing any votes.
SYSTEMS
The systems class contains information about the systems in the cluster. This class includes information such as the system ID, the node name, the type of system, the type of software, the software version, the number of virtual circuits, etc. The fields which make up the systems class are:
Additional information available:
DG_SIZEHW_VERSHW_TYPEINCARNATIONMSG_SIZENODE
NUM_CIRCUITSSOFTWARESYS_ID
DG_SIZE
The DG_SIZE field displays the maximum number of bytes of application data in datagrams transferred over the circuit.
HW_VERS
If the remote system is an HSC then the twelve bytes displayed
in this field reflect the hardware type and microcode level of one
of six requestors in the HSC. The left byte in each pair is the
hardware type, the right byte is the microcode version. If zeros
appear in both bytes, then the requestor is not present. The
requestors are numbered 2 through 7 as shown in the following
table. T is the hardware type. V is the microcode version.
Req. 7 Req. 6 Req. 5 Req. 4 Req. 3 Req. 2
+----+----+----+----+----+----+----+----+----+----+----+----+
| T V | T V | T V | T V | T V | T V |
+----+----+----+----+----+----+----+----+----+----+----+----+
If the remote system is a VAX, then the lower four bytes
reflect the contents of the system ID register for the processor.
The upper two bytes contain the CPU model number. The remaining
six bytes are processor specific and are defined as shown in the
following table:
B3 B4 B5 B6 B7 B8
+---------+---------+---------+---------+---------+---------+
8600 | unused | Processor |
+---------+---------+---------+---------+---------+---------+
785 | WCS (1) |flags (2)| WCS | PCS(3)| PCS |
+---------+---------+---------+---------+---------+---------+
780/782 | WCS (1) |flags (2)| WCS | PCS | FPLA |
+---------+---------+---------+---------+---------+---------+
750 | unused |
+---------+---------+---------+---------+---------+---------+
All fields unless noted below refer to microcode revision levels.
(1) WCS size
(2) FPA, G and H floating flags
(3) PCS/WCA match revision
HW_TYPE
The HW_TYPE field displays the type of hardware or processor type
of the remote system.
NOTE: The hardware-types displayed in this field can be used with
the ADD and REMOVE SYSTEM/TYPE=("hw-type",...) commands.
INCARNATION
The value displayed in the INCARNATION field is a unique 16 digit (hex) number established when the system is booted.
MSG_SIZE
The MSG_SIZE field displays the maximum number of bytes of application data in messages transferred over the circuit.
NODE
The NODE field displays the nodename of the remote system.
The nodename is determined by the SYSGEN parameter SCSNODE
and should be the same the DECnet nodename.
NOTE: The node-names displayed in this field can be used with the
ADD and REMOVE SYSTEM/NODE=(node-name,...) commands.
NUM_CIRCUITS
The NUM_CIRCUITS field displays a count of the number of virtual circuits established between the local and the remote system.
SOFTWARE
The SOFTWARE field displays the name and version of the operating system being run on the remote system.
SYS_ID
The SYS_ID field displays identification number of the remote system.
This ID number is determined by the SYSGEN parameters SCSSYSTEMID and
SCSSYSTEMIDH. The system-id should be the same as the DECnet node
address.
NOTE: The system-ids displayed in this field can be used with the
ADD and REMOVE SYSTEM/ID=(system-id,...) commands.
MEMBERS
The members class contains information about the systems that are actively participating in the cluster. This class includes fields such as the system's cluster-wide ID number and the system's membership status in the cluster. The fields which make up the MEMBERS class are:
Additional information available:
ACKR_SQACK_LMCNX_STATECSIDDIR_WTEXPECTED_VOTES
PROTOCOLQDVOTESQF_ACTIVEQF_SAMEQUORUMRCVD_SQ
RECNXINTERVALSEND_SQSTATUSSW_VERSTRANSITION_TIME
UNACKEDVOTESWARMCDRPS
ACKR_SQ
The ACKR_SQ field displays the sequence number of the last acknowledge received via the VAXcluster connection.
ACK_LM
The ACK_LM field displays the maximum number of VAXcluster messages that can be received by the remote system before an acknowledgment reply is sent.
CNX_STATE
The CNX_STATE field displays the state of the VAXcluster connection.
The possible displays are:
ACCEPT Accepting the initial connection.
CLOSED The connection is closed.
CONNECT Attempting the initial connection.
DEAD No connection is possible.
DISCONNECT A disconnection is in progress.
NEW No attempt to make a connection has been made yet.
OPEN The connection is open.
REACCEPT The connection is accepting the reconnect request.
RECONNECT The connection is attempting to reconnect.
WAIT A time-out is in progress.
CSID
The Cluster System ID.
DIR_WT
The DIR_WT field displays the Lock Manager distributed directory weight as determined by the LOCKDIRWT SYSGEN parameter.
EXPECTED_VOTES
The EXPECTED_VOTES field displays the number of votes which are expected to be contributed by all members of the cluster as set by the EXPECTED_VOTES SYSGEN parameter.
PROTOCOL
The PROTOCOL field displays the protocol version number and ECO level of the connection management software.
QDVOTES
The QDVOTES field displays number of votes which the remote system recommends be contributed by the quorum disk. The recommended number of votes is determined by the SYSGEN QDVOTES parameter.
QF_ACTIVE
The QF_ACTIVE field indicates whether or not the remote system's quorum file is accessible.
QF_SAME
The QF_SAME field indicates whether or not the remote system and local system agree as to which disk is the quorum disk.
QUORUM
The QUORUM field displays the recommended quorum value derived from the EXPECTED_VOTES value.
RCVD_SQ
The RCVD_SQ field displays the sequence number of the last message to be received via the VAXcluster connection.
RECNXINTERVAL
The RECNXINTERVAL field displays the amount of time (in seconds) that the connection manager will wait before timing out its connection. The value displayed is the maximum of the intervals set on the local and remote nodes as determined by the RECNXINTERVAL SYSGEN parameter.
SEND_SQ
The SEND_SQ field displays the sequence number of the next message to be sent via the VAXcluster connection.
STATUS
The STATUS field indicates the remote system's membership status in
the cluster. The possible displays are:
(blank) The system is not being considered for cluster
membership.
BRK_MEM The system is a member of the cluster, but the
connection manager has lost communication with it.
BRK_NEW The system has just booted, but has not yet joined
the cluster and the connection manager has lost
communication with it.
BRK_NON The connection manager has lost communication with
the system and the system is no longer a member of
the cluster. It is now a non-member.
BRK_REM The connection manager has lost communication with
the system and the system has been removed from the
cluster.
MEMBER The system is participating in the cluster (A default
SYSGEN parameter allows 90 seconds delay before a
failing system is removed from cluster membership
status.)
NEW The system has just booted, but has not yet joined
the cluster. If this system would normally be a member
of the cluster, and is displaying NEW in this field,
you can expect that the display will eventually change
to MEMBER.
NON The system is not a member of the cluster.
REMOVED The system has been removed from the cluster.
SW_VERS
The SW_VERS field contains a numeric representation of the software version running on the node.
TRANSITION_TIME
The TRANSITION_TIME field displays the time of the system's last change in membership status.
UNACKED
The UNACKED field displays the number of unacknowledged VAXcluster messages received by the remote system.
VOTES
The VOTES field displays the number of votes the remote system contributes toward quorum. The number of votes contributed is determined by the SYSGEN VOTES parameter.
WARMCDRPS
The WARMCDRPS field displays a count of the number of CDRPS on the CDRP free queue. For additional information, see help on classes MEMBERS STATUS.
CIRCUITS
The circuits class contains information about the virtual circuits on a system. This class includes fields such as local port name, remote port type and number, number of connections on the circuit, circuit state, etc. The fields which make up the circuits class are:
Additional information available:
CABLE_STATUSCIR_STATELPORT_NAMENUM_CONNECTIONS
REM_STATERPORT_NUMRP_FUNCTIONSRP_OWNER
RP_REVISIONRP_TYPESCS_WAITERS
CABLE_STATUS
The CABLE_STATUS field indicates status of the path for the circuit
from the CI interface on the local system to the CI interface on the
remote system. The field indicates which of the two paths (A and B)
are good, or if the cables are crossed. The possible displays are:
- Paths A and B are bad.
A- Path A is good.
-B Path B is good.
A-B Paths A and B are good.
CROSSED The cables are crossed.
CIR_STATE
The CIR_STATE field displays the state of the virtual circuit. The
circuit may be OPEN, CLOSED, in one of the open or close in
progress states, or VC_FAIL. The possible displays are:
CLOSED The circuit is closed.
OPEN The circuit is opened.
ST_REC The circuit has a start received.
ST_SENT The circuit has a start sent.
VC_FAIL A virtual circuit failure is in progress.
LPORT_NAME
The LPORT_NAME field displays the VMS device name of the local port associated with the circuit.
NUM_CONNECTIONS
The NUM_CONNECTIONS field is a count of the number of connections established on the circuit between the local and remote system.
REM_STATE
The REM_STATE field indicates the state of the port on the remote system.
The possible displays are:
DISAB The remote port is disabled.
ENAB The remote port is enabled.
M_DISAB The remote port is in maintenance mode, and is
disabled.
M_ENAB The remote port is in maintenance mode and is
enabled.
M_UNINIT The remote port is in maintenance mode, and has
not been initialized.
UNINIT The remote port has not been initialized.
RPORT_NUM
The RPORT_NUM field displays the number of the port on the remote system associated with the circuit.
RP_FUNCTIONS
The RP_FUNCTIONS field displays the function mask of port on the remote system.
RP_OWNER
The RP_OWNER field displays the port number of the owner of the port on the remote system.
RP_REVISION
The RP_REVISION field indicates the hardware and/or microcode revision number of port on the remote system.
RP_TYPE
The RP_TYPE field displays the type of port on the remote system
associated with the circuit. The possible displays are:
CI780 ETHERNET
CI750 HSC50
CIBCA CINT (CI node tester)
CIBCI PASSTH (port is in pass-through mode)
BVPSSP
SCS_WAITERS
The SCS_WAITERS field displays a count of the number of connections waiting to send SCS control messages on the virtual circuit.
CONNECTIONS
The connections class contains information about the connection established over a virtual circuit. This class includes fields such as the names and ID numbers of the local and remote processes, and the state of the connection. The fields which make up the connections class are:
Additional information available:
CON_STATELOC_CONIDLOC_PROC_NAMEREM_CONID
REM_PROC_NAMESCS_STATE
CON_STATE
The CON_STATE field displays the state of the connection.
The possible displays are:
ACCP_SENT An accept request has been sent.
CLOSED The connection is closed.
CON_ACK A connect request has been sent and acknowledged.
CON_REC A connect request has been received.
CON_SENT A connect request has been sent.
DISC_ACK A disconnect is acknowledged.
DISC_MTCH A disconnect request has matched.
DISC_REC A disconnect request has been received.
DISC_SENT A disconnect request has been sent.
LISTEN The connection is in the listen state.
OPEN The connection is open.
REJ_SENT A reject has been sent.
VC_FAIL The virtual circuit has failed.
LOC_CONID
The LOC_CONID field displays the identification number of the process on the local system associated with the connection.
LOC_PROC_NAME
The LOC_PROC_NAME field displays the name of the process on the local system associated with the connection.
REM_CONID
The REM_CONID field displays the identification number of the process on the remote system associated with the connection. This information is not available for connections in the listen state.
REM_PROC_NAME
The REM_PROC_NAME field displays the name of the process on the remote system associated with the connection. This information is not available for connections in the listen state.
SCS_STATE
The SCS_STATE field displays the SCS send blocked state. If the
an SCS control message is waiting to be sent over the connection,
the SCS send blocked state indicates what kind of message is
waiting to be sent. The possible displays are:
ACCP_PEND Waiting to send an accept request.
CLEAR Not blocked.
CON_PEND Waiting to send a connection request.
CR_PEND Waiting to send credit.
DCR_PEND Waiting to send credit in preparation for a
disconnect.
DISC_PEND Waiting to send a disconnect request.
REJ_PEND Waiting to send a reject request.
COUNTERS
The counters class displays the counts for the total accumulated traffic over a connection for the life of the connection. This class includes fields such as the number of application datagrams sent and received, the number of application messages sent and received, and the number of kilobytes sent and requested in block transfer mode.
Additional information available:
BDT_WAITSBLKS_REQBLKS_SENTCR_WAITSDGS_DSCRD
DGS_RCVDDGS_SENTKB_MAPPEDKB_RCVDKB_SENTMSGS_RCVD
MSGS_SENT
BDT_WAITS
The BDT_WAITS field is a count of the number of times this connection had to wait for a buffer descriptor.
BLKS_REQ
The BLKS_REQ field is a count of the number of block request datas initiated to block transfer data from the remote to the local system.
BLKS_SENT
The BLKS_SENT field is a count of the number of block send datas initiated to block transfer data from the local to the remote system.
CR_WAITS
The CR_WAITS field is a count of the number of times this connection had to wait for send credit.
DGS_DSCRD
The DGS_DSCRD field is a count of the number of application datagrams discarded by the port driver.
DGS_RCVD
The DGS_RCVD field is a count of the number of application datagrams received from the remote system by the local system and given to the sysap.
DGS_SENT
The DGS_SENT field is a count of the number of application datagrams sent over the connection from the local to the remote system.
KB_MAPPED
The KB_MAPPED field displays the number of kilobytes mapped for block transfer.
KB_RCVD
The KB_RCVD field is a count of the number of kilobytes of data received by the local from the remote system via request datas.
KB_SENT
The KB_SENT field is a count of the number of kilobytes of data sent from the local to the remote system via send datas.
MSGS_RCVD
The MSGS_RCVD field is a count of the number of messages received over the connection by the local system from the remote system.
MSGS_SENT
The MSGS_SENT field is a count of the number of messages sent over the connection from the local to the remote system.
CREDITS
The credits class displays the send and receive credit counts for each connection. This class includes fields that indicate the minimum, current and initial credit counts. The fields which make up the credits class are:
Additional information available:
INIT_RECMIN_RECMIN_SENDPEND_RECRECEIVESEND
INIT_REC
Initial receive credit extended to remote when connection was made.
MIN_REC
Minimum receive credit. (Minimum send credit required by remote.)
MIN_SEND
Minimum send credit.
PEND_REC
Receive credit not yet extended to remote.
RECEIVE
Receive credit. (Send credit held by remote.)
SEND
Current send credit.
LOCAL_PORTS
The local ports class displays information regarding the port interface on the local system. This class includes fields such as the port name, port number, port status, and the number of entries in the queues associated with each port. The fields which make up the local port class are:
Additional information available:
CMDS_QUEUEDCOUNTER_OWNERDGI_MAPDGS_FREEDG_OVRHD_SIZE
FORM_CIRCSLB_STATUSLOG_MAPLP_STATUS
LP_TYPEMAX_PORTMSGS_FREEMSG_HDR_SIZE
NAMEOPEN_CIRCSPOOL_WAITERSPORT_NUM
PRT_MAPRSPS_QUEUED
CMDS_QUEUED
Total number of messages, datagrams, and port commands queued for transmission at all priorities by the port.
COUNTER_OWNER
The name of the process currently using the port traffic counters.
DGI_MAP
A sixteen bit bit-map displayed as 4 hex digits. Each bit in the map represents a port in the cluster from which datagram reception has been disabled.
DGS_FREE
The number of free datagram buffers currently queued for receives.
DG_OVRHD_SIZE
The number of bytes of port header, SCS header, and DECnet header in a datagram.
FORM_CIRCS
The number of formative circuits from the port. (i.e. virtual circuits with open-in-progress)
LB_STATUS
The loop-back status of each cable from the port to the star coupler.
The possible displays are:
A-B Loopback tests pass on paths A and B.
A- Loopback tests pass on path A.
-B Loopback tests pass on path B.
- Loopback tests failed on paths A and B
N/A Loopback tests are not being done.
LOG_MAP
A sixteen bit bit-map displayed as 4 hex digits. Each bit in the map represents a port in the cluster for which an error has been logged upon the discovery of conflicting data between the information in the configuration database on the local system and the information provided by the remote system. Once set, establishment of a virtual circuit to the remote system is no longer allowed.
LP_STATUS
Status of the local port. (i.e. online, offline)
LP_TYPE
The device type of the local port. (i.e. CI780, CI750, etc.)
MAX_PORT
The largest port number to which we try to open a virtual circuit.
MSGS_FREE
The number of free message buffers currently queued for receives.
MSG_HDR_SIZE
The number of bytes of port header and SCS header in a message.
NAME
The VMS device name of the local port.
OPEN_CIRCS
The number of virtual circuits open from the port.
POOL_WAITERS
The number of processes waiting for non-paged pool resources for message buffers.
PORT_NUM
The port number assigned to the port.
PRT_MAP
A sixteen bit bit-map displayed as 3 hex digits. Each bit in the map represents a port in the cluster that has been recognized by the host system.
RSPS_QUEUED
Total number of responses of all kinds received from the port, but not yet processed.
ERRORS
The errors class displays a running count of the errors on each port along with the current number of reinitialization attempts remaining and the maximum number of times reinitialization can be attempted. The fields which make up the errors class are:
Additional information available:
ERT_COUNT
The number of port reinitialization attempts remaining.
ERT_MAX
The total number of times a recovery from fatal port errors can be attempted by shutting down all virtual circuits and connections and reinitializing the port.
NUM_ERRORS
The number of errors that have been logged on the port since the system was booted. This includes errors encountered in reinitialization attempts as well as recoverable errors such as virtual circuit failure.
Fields
The fields available for display are: ACKR_SQ ACK_LM BDT_WAITS BLKS_REQ BLKS_SENT CABLE_STATUS CIR_STATE CL_EXPECTED_VOTES CL_MEMBERS CL_QDVOTES CL_QUORUM CL_VOTES CMDS_QUEUED CNX_STATE CON_STATE COUNTER_OWNER CR_WAITS CSID DGI_MAP DGS_DSCRD DGS_FREE DGS_RCVD DGS_SENT DG_OVRHD_SIZE DG_SIZE DIR_WT ERT_COUNT ERT_MAX EXPECTED_VOTES FORMED FORM_CIRCS HW_TYPE HW_VERS INCARNATION INIT_REC KB_MAPPED KB_RCVD KB_SENT LAST_TRANSITION LB_STATUS LOC_CONID LOC_PROC_NAME LOG_MAP LPORT_NAME LP_STATUS LP_TYPE MAX_PORT MEMSEQ MIN_REC MIN_SEND MSGS_FREE MSGS_RCVD MSGS_SENT MSG_HDR_SIZE MSG_SIZE NAME NODE NUM_CIRCUITS NUM_CONNECTIONS NUM_ERRORS OPEN_CIRCS PEND_REC POOL_WAITERS PORT_NUM PROTOCOL PRT_MAP QDVOTES QD_NAME QF_ACTIVE QF_SAME QF_VOTE QUORUM RCVD_SQ RECEIVE RECNXINTERVAL REM_CONID REM_PROC_NAME REM_STATE RPORT_NUM RP_FUNCTIONS RP_OWNER RP_REVISION RP_TYPE RSPS_QUEUED SCS_STATE SCS_WAITERS SEND SEND_SQ SOFTWARE STATUS SW_VERS SYS_ID TRANSITION_TIME UNACKED VOTES WARMCDRPS
Additional information available:
ACKR_SQACK_LMBDT_WAITSBLKS_REQBLKS_SENT
CABLE_STATUSCIR_STATECL_EXPECTED_VOTESCL_MEMBERS
CL_QDVOTESCL_QUORUMCL_VOTESCMDS_QUEUED
CNX_STATECON_STATECOUNTER_OWNERCR_WAITS
CSIDDGI_MAPDGS_FREEDGS_DSCRDDGS_RCVDDGS_SENT
DG_OVRHD_SIZEDG_SIZEDIR_WTERT_COUNTERT_MAX
EXPECTED_VOTESFORMEDFORM_CIRCSHW_TYPEHW_VERS
INCARNATIONINIT_RECKB_MAPPEDKB_RCVDKB_SENT
LAST_TRANSITIONLB_STATUSLOC_CONIDLOC_PROC_NAME
LOG_MAPLPORT_NAMELP_STATUSLP_TYPEMAX_PORT
MEMSEQMIN_RECMIN_SENDMSGS_FREEMSGS_RCVD
MSGS_SENTMSG_HDR_SIZEMSG_SIZENAMENODE
NUM_CIRCUITSNUM_CONNECTIONSNUM_ERRORSOPEN_CIRCS
PEND_RECPOOL_WAITERSPORT_NUMPROTOCOLPRT_MAP
QDVOTESQD_NAMEQF_ACTIVEQF_SAMEQF_VOTEQUORUM
RCVD_SQRECEIVERECNXINTERVALREM_CONIDREM_PROC_NAME
REM_STATERPORT_NUMRP_FUNCTIONSRP_OWNER
RP_REVISIONRP_TYPERSPS_QUEUEDSCS_STATESCS_WAITERS
SENDSEND_SQSOFTWARESTATUSSYS_IDSW_VERSTRANSITION_TIME
UNACKEDVOTESWARMCDRPS
ACKR_SQ
The ACKR_SQ field displays the sequence number of the last acknowledge received via the VAXcluster connection.
ACK_LM
The ACK_LM field displays the maximum number of VAXcluster messages that can be received by the remote system before an acknowledgment reply is sent.
BDT_WAITS
The BDT_WAITS field is a count of the number of times this connection had to wait for a buffer descriptor.
BLKS_REQ
The BLKS_REQ field is a count of the number of block request datas initiated to block transfer data from the remote to the local system.
BLKS_SENT
The BLKS_SENT field is a count of the number of block send datas initiated to block transfer data from the local to the remote system.
CABLE_STATUS
The CABLE_STATUS field indicates status of the path for the circuit
from the CI interface on the local system to the CI interface on the
remote system. The field indicates which of the two paths (A and B)
are good, or if the cables are crossed. The possible displays are:
- Paths A and B are bad.
A- Path A is good.
-B Path B is good.
A-B Paths A and B are good.
CROSSED The cables are crossed.
CIR_STATE
The CIR_STATE field displays the state of the virtual circuit. The
circuit may be OPEN, CLOSED, in one of the open or close in
progress states, or VC_FAIL. The possible displays are:
CLOSED The circuit is closed.
OPEN The circuit is opened.
ST_REC The circuit has a start received.
ST_SENT The circuit has a start sent.
VC_FAIL A virtual circuit failure is in progress.
CL_EXPECTED_VOTES
The CL_EXPECTED_VOTES field displays the number of votes expected to be contributed by all members of the cluster as determined by the connection manager. This value is based on the maximum of EXPECTED_VOTES and the maximized value of CL_VOTES.
CL_MEMBERS
The CL_MEMBERS field displays the number of systems which are currently members of the cluster.
CL_QDVOTES
The CL_QDVOTES field displays the number of quorum votes currently being contributed by the quorum disk.
CL_QUORUM
The CL_QUORUM field displays the number of votes required for the cluster to have quorum.
CL_VOTES
THE CL_VOTES field displays the total number of quorum votes currently being contributed by all cluster members and the quorum disk.
CMDS_QUEUED
Total number of messages, datagrams, and port commands queued for transmission at all priorities by the port.
CNX_STATE
The CNX_STATE field displays the state of the VAXcluster connection.
The possible displays are:
ACCEPT Accepting the initial connection.
CLOSED The connection is closed.
CONNECT Attempting the initial connection.
DEAD No connection is possible.
DISCONNECT A disconnection is in progress.
NEW No attempt to make a connection has been made yet.
OPEN The connection is open.
REACCEPT The connection is accepting the reconnect request.
RECONNECT The connection is attempting to reconnect.
WAIT A time-out is in progress.
CON_STATE
The CON_STATE field displays the state of the connection.
The possible displays are:
ACCP_SENT An accept request has been sent.
CLOSED The connection is closed.
CON_ACK A connect request has been sent and acknowledged.
CON_REC A connect request has been received.
CON_SENT A connect request has been sent.
DISC_ACK A disconnect is acknowledged.
DISC_MTCH A disconnect request has matched.
DISC_REC A disconnect request has been received.
DISC_SENT A disconnect request has been sent.
LISTEN The connection is in the listen state.
OPEN The connection is open.
REJ_SENT A reject has been sent.
VC_FAIL The virtual circuit has failed.
COUNTER_OWNER
The name of the process currently using the port traffic counters.
CR_WAITS
The CR_WAITS field is a count of the number of times this connection had to wait for send credit.
CSID
The Cluster System ID.
DGI_MAP
A sixteen bit bit-map displayed as 4 hex digits. Each bit in the map represents a port in the cluster from which datagram reception has been disabled.
DGS_FREE
The number of free datagram buffers currently queued for receives.
DGS_DSCRD
The DGS_DSCRD field is a count of the number of application datagrams discarded by the port driver.
DGS_RCVD
The DGS_RCVD field is a count of the number of application datagrams received from the remote system by the local system and given to the sysap.
DGS_SENT
The DGS_SENT field is a count of the number of application datagrams sent over the connection from the local to the remote system.
DG_OVRHD_SIZE
The number of bytes of port header, SCS header, and DECnet header in a datagram.
DG_SIZE
The DG_SIZE field displays the maximum number of bytes of application data in datagrams transferred over the circuit.
DIR_WT
The DIR_WT field displays the Lock Manager distributed directory weight as determined by the LOCKDIRWT SYSGEN parameter.
ERT_COUNT
The number of port reinitialization attempts remaining.
ERT_MAX
The total number of times a recovery from fatal port errors can be attempted by shutting down all virtual circuits and connections and reinitializing the port.
EXPECTED_VOTES
The EXPECTED_VOTES field displays the number of votes which are expected to be contributed by all members of the cluster as set by the EXPECTED_VOTES SYSGEN parameter.
FORMED
The time at which the cluster was formed. (DD-MMM-YY HH:MM).
FORM_CIRCS
The number of formative circuits from the port. (i.e. virtual circuits with open-in-progress)
HW_TYPE
The HW_TYPE field displays the type of hardware or processor type
of the remote system.
NOTE: The hardware-types displayed in this field can be used with
the ADD and REMOVE SYSTEM/TYPE=("hw-type",...) commands.
HW_VERS
If the remote system is an HSC then the twelve bytes displayed
in this field reflect the hardware type and microcode level of one
of six requestors in the HSC. The left byte in each pair is the
hardware type, the right byte is the microcode version. If zeros
appear in both bytes, then the requestor is not present. The
requestors are numbered 2 through 7 as shown in the following
table. T is the hardware type. V is the microcode version.
Req. 7 Req. 6 Req. 5 Req. 4 Req. 3 Req. 2
+----+----+----+----+----+----+----+----+----+----+----+----+
| T V | T V | T V | T V | T V | T V |
+----+----+----+----+----+----+----+----+----+----+----+----+
If the remote system is a VAX, then the lower four bytes
reflect the contents of the system ID register for the processor.
The upper two bytes contain the CPU model number. The remaining
six bytes are processor specific and are defined as shown in the
following table:
B3 B4 B5 B6 B7 B8
+---------+---------+---------+---------+---------+---------+
8600 | unused | Processor |
+---------+---------+---------+---------+---------+---------+
785 | WCS (1) |flags (2)| WCS | PCS(3)| PCS |
+---------+---------+---------+---------+---------+---------+
780/782 | WCS (1) |flags (2)| WCS | PCS | FPLA |
+---------+---------+---------+---------+---------+---------+
750 | unused |
+---------+---------+---------+---------+---------+---------+
All fields unless noted below refer to microcode revision levels.
(1) WCS size
(2) FPA, G and H floating flags
(3) PCS/WCA match revision
INCARNATION
The value displayed in the INCARNATION field is a unique 16 digit (hex) number established when the system is booted.
INIT_REC
Initial receive credit extended to remote when connection was made.
KB_MAPPED
The KB_MAPPED field displays the number of kilobytes mapped for block transfer.
KB_RCVD
The KB_RCVD field is a count of the number of kilobytes of data received by the local from the remote system via request datas.
KB_SENT
The KB_SENT field is a count of the number of kilobytes of data sent from the local to the remote system via send datas.
LAST_TRANSITION
The LAST_TRANSITION time is the time at which a system last left or joined the cluster. (DD-MMM-YY HH:MM)
LB_STATUS
The loop-back status of each cable from the port to the star coupler.
The possible displays are:
A-B Loopback tests pass on paths A and B.
A- Loopback tests pass on path A.
-B Loopback tests pass on path B.
- Loopback tests failed on paths A and B
N/A Loopback tests are not being done.
LOC_CONID
The LOC_CONID field displays the identification number of the process on the local system associated with the connection.
LOC_PROC_NAME
The LOC_PROC_NAME field displays the name of the process on the local system associated with the connection.
LOG_MAP
A sixteen bit bit-map displayed as 4 hex digits. Each bit in the map represents a port in the cluster for which an error has been logged upon the discovery of conflicting data between the information in the configuration database on the local system and the information provided by the remote system. Once set, establishment of a virtual circuit to the remote system is no longer allowed.
LPORT_NAME
The LPORT_NAME field displays the VMS device name of the local port associated with the circuit.
LP_STATUS
Status of the local port. (i.e. online, offline)
LP_TYPE
The device type of the local port. (i.e. CI780, CI750, etc.)
MAX_PORT
The largest port number to which we try to open a virtual circuit.
MEMSEQ
The MEMSEQ field displays the membership state sequence number.
MIN_REC
Minimum receive credit. (Minimum send credit required by remote.)
MIN_SEND
Minimum send credit.
MSGS_FREE
The number of free message buffers currently queued for receives.
MSGS_RCVD
The MSGS_RCVD field is a count of the number of messages received over the connection by the local system from the remote system.
MSGS_SENT
The MSGS_SENT field is a count of the number of messages sent over the connection from the local to the remote system.
MSG_HDR_SIZE
The number of bytes of port header and SCS header in a message.
MSG_SIZE
The MSG_SIZE field displays the maximum number of bytes of application data in messages transferred over the circuit.
NAME
The VMS device name of the local port.
NODE
The NODE field displays the nodename of the remote system.
The nodename is determined by the SYSGEN parameter SCSNODE
and should be the same the DECnet nodename.
NOTE: The node-names displayed in this field can be used with the
ADD and REMOVE SYSTEM/NODE=(node-name,...) commands.
NUM_CIRCUITS
The NUM_CIRCUITS field displays a count of the number of virtual circuits established between the local and the remote system.
NUM_CONNECTIONS
The NUM_CONNECTIONS field is a count of the number of connections established on the circuit between the local and remote system.
NUM_ERRORS
The number of errors that have been logged on the port since the system was booted. This includes errors encountered in reinitialization attempts as well as recoverable errors such as virtual circuit failure.
OPEN_CIRCS
The number of virtual circuits open from the port.
PEND_REC
Receive credit not yet extended to remote.
POOL_WAITERS
The number of processes waiting for non-paged pool resources for message buffers.
PORT_NUM
The port number assigned to the port.
PROTOCOL
The PROTOCOL field displays the protocol version number and ECO level of the connection management software.
PRT_MAP
A sixteen bit bit-map displayed as 4 hex digits. Each bit in the map represents a port in the cluster that has been recognized by the host system.
QDVOTES
The QDVOTES field displays number of votes which the remote system recommends be contributed by the quorum disk. The recommended number of votes is determined by the SYSGEN QDVOTES parameter.
QD_NAME
The full device name of the quorum disk.
QF_ACTIVE
The QF_ACTIVE field indicates whether or not the remote system's quorum file is accessible.
QF_SAME
The QF_SAME field indicates whether or not the remote system and local system agree as to which disk is the quorum disk.
QF_VOTE
The QF_VOTE field indicates whether or not the quorum disk is contributing any votes.
QUORUM
The QUORUM field displays the recommended quorum value derived from the EXPECTED_VOTES value.
RCVD_SQ
The RCVD_SQ field displays the sequence number of the last message to be received via the VAXcluster connection.
RECEIVE
Receive credit. (Send credit held by remote.)
RECNXINTERVAL
The RECNXINTERVAL field displays the amount of time (in seconds) that the connection manager will wait before timing out its connection. The value displayed is the maximum of the intervals set on the local and remote nodes as determined by the RECNXINTERVAL SYSGEN parameter.
REM_CONID
The REM_CONID field displays the identification number of the process on the remote system associated with the connection. This information is not available for connections in the listen state.
REM_PROC_NAME
The REM_PROC_NAME field displays the name of the process on the remote system associated with the connection. This information is not available for connections in the listen state.
REM_STATE
The REM_STATE field indicates the state of the port on the remote system.
The possible displays are:
DISAB The remote port is disabled.
ENAB The remote port is enabled.
M_DISAB The remote port is in maintenance mode, and is
disabled.
M_ENAB The remote port is in maintenance mode and is
enabled.
M_UNINIT The remote port is in maintenance mode, and has
not been initialized.
UNINIT The remote port has not been initialized.
RPORT_NUM
The RPORT_NUM field displays the number of the port on the remote system associated with the circuit.
RP_FUNCTIONS
The RP_FUNCTIONS field displays the function mask of port on the remote system.
RP_OWNER
The RP_OWNER field displays the port number of the owner of the port on the remote system.
RP_REVISION
The RP_REVISION field indicates the hardware and/or microcode revision number of port on the remote system.
RP_TYPE
The RP_TYPE field displays the type of port on the remote system
associated with the circuit. The possible displays are:
CI780 ETHERNET
CI750 HSC50
CIBCA CINT (CI node tester)
CIBCI PASSTH (port is in pass-through mode)
BVPSSP
RSPS_QUEUED
Total number of responses of all kinds received from the port, but not yet processed.
SCS_STATE
The SCS_STATE field displays the SCS send blocked state. If the
an SCS control message is waiting to be sent over the connection,
the SCS send blocked state indicates what kind of message is
waiting to be sent. The possible displays are:
ACCP_PEND Waiting to send an accept request.
CLEAR Not blocked.
CON_PEND Waiting to send a connection request.
CR_PEND Waiting to send credit.
DCR_PEND Waiting to send credit in preparation for a
disconnect.
DISC_PEND Waiting to send a disconnect request.
REJ_PEND Waiting to send a reject request.
SCS_WAITERS
The SCS_WAITERS field displays a count of the number of connections waiting to send SCS control messages on the virtual circuit.
SEND
Current send credit.
SEND_SQ
The SEND_SQ field displays the sequence number of the next message to be sent via the VAXcluster connection.
SOFTWARE
The SOFTWARE field displays the name and version of the operating system being run on the remote system.
STATUS
The STATUS field indicates the remote system's membership status in
the cluster. The possible displays are:
(blank) The system is not being considered for cluster
membership.
BRK_MEM The system is a member of the cluster, but the
connection manager has lost communication with it.
BRK_NEW The system has just booted, but has not yet joined
the cluster and the connection manager has lost
communication with it.
BRK_NON The connection manager has lost communication with
the system and the system is no longer a member of
the cluster. It is now a non-member.
BRK_REM The connection manager has lost communication with
the system and the system has been removed from the
cluster.
MEMBER The system is participating in the cluster (A default
SYSGEN parameter allows 90 seconds delay before a
failing system is removed from cluster membership
status.)
NEW The system has just booted, but has not yet joined
the cluster. If this system would normally be a member
of the cluster, and is displaying NEW in this field,
you can expect that the display will eventually change
to MEMBER.
NON The system is not a member of the cluster
REMOVED The system has been removed from the cluster.
SYS_ID
The SYS_ID field displays identification number of the remote system.
This ID number is determined by the SYSGEN parameters SCSSYSTEMID and
SCSSYSTEMIDH. The system-id should be the same as the DECnet node
address.
NOTE: The system-ids displayed in this field can be used with the
ADD and REMOVE SYSTEM/ID=(system-id,...) commands.
SW_VERS
The SW_VERS field contains a numeric representation of the software version running on the node.
TRANSITION_TIME
The TRANSITION_TIME field displays the time of the system's last change in membership status. For additional information, see help on field STATUS.
UNACKED
The UNACKED field displays the number of unacknowledged VAXcluster messages received by the remote system.
VOTES
The VOTES field displays the number of votes the remote system contributes toward quorum. The number of votes contributed is determined by the SYSGEN VOTES parameter.
WARMCDRPS
The WARMCDRPS field displays a count of the number of CDRPS on the CDRP free queue.
Procedure
Requests the internal command interpreter to read subsequent command
input from a specific file or device. The file may contain any valid
interactive command. Command files may be nested to 16 levels. The
file type defaults to .COM.
Format:
@file-spec
Note: If the logical name SHOW_CLUSTER$INIT is defined, then Show
Cluster will use the directory defined by SHOW_CLUSTER$INIT
to locate the command file specified. If SHOW_CLUSTER$INIT
is not defined Show Cluster will look for the command file
in the current default directory.
To execute a command procedure upon invoking SHOW CLUSTER define the
logical name SHOW_CLUSTER$INIT to equate to the filespec you would like
SHOW CLUSTER to execute. The file type defaults to .INI.