SYSGEN SET — MicroVMS 4.6
Assigns a value to a system parameter as it exists in the SYSGEN work
area.
Format
SET parameter-name value
This command does not modify parameter files, the system image on disk,
or the active system. See the WRITE command for these functions.
Example
SET PFCDEFAULT 20
Additional information available:
parameter-name
Name of a system parameter. Use the SHOW /NAMES command to obtain the names of all the system parameters.
value
An integer value or the keyword DEFAULT; integer values must be within the minimum/maximum values unless DISABLE CHECKS was specified; DEFAULT means the default value for the parameter.
Qualifiers
Additional information available:
/OUTPUT = file-spec
Specifies that any output from subsequent commands is to be directed to an output file.
/STARTUP
Defines the name of the command procedure to be executed when the
system is booted.
Format
SET/STARTUP file-spec
The default startup command procedure is SYS$SYSTEM:STARTUP.COM. The
file specification can be a maximum of 31 characters long.