SYSGEN CONFIGURE — MicroVMS 4.4

Prompts by "DEVICE>" and accepts UNIBUS device names.
Output is the set of CSR and vector addresses that AUTOCONFIGURE will use.

Form of input:

                device[,n[,p]]  (Default n = 1, p = 0)

          where n is the number of devices on the UNIBUS being
          configured and p is the optional number of devices
          on all previous UNIBUS in a mulitple UNIBUS system.
          Note that p does not affect the addresses generated,
          only the device names.

Additional information available:

Qualifiers

Qualifiers

Additional information available:

/INPUT/OUTPUT/NORESET

/INPUT = (D=SYS$INPUT)

Specifies where input is to be read from.

/OUTPUT = (D=SYS$OUTPUT)

Specifies where output is to be written to.

/NORESET

For use on multiple UNIBUS systems. Used on subsequent CONFIGURE commands
to not reset controller names, so that the second input parameter is
unnecessary.