tcdrain(3C)
NAME
tcdrain, tcflow, tcflush, tcsendbreak − Perform terminal line control operations.
SYNOPSIS
#include <termios.h>
int tcdrain (fildes)
int fildes;
int tcflow (fildes, action)
int fildes;
int action;
int tcflush (fildes, queue_selector)
int fildes;
int queue_selector;
int tcsendbreak (fildes, duration)
int fildes;
int duration;
DESCRIPTION
The tcdrain(), tcflow(), tcflush(), and tcsendbreak() functions are defined in the POSIX 1003.1 standard and used in the OCS and BCS standards. CX/UX applications which are not POSIX/OCS/BCS compliant can use these functions.
Background processes may not call these functions. Attempts to do so will result in a SIGTTOU signal being sent to the calling process and all members of its process group. The SIGTTOU signal stops the calling process and all members of its process group unless the calling process is blocking or ignoring this signal.
tcdrain waits until all output written to the terminal device referenced by fildes has been transmitted (drained).
Tcflow suspends transmission or reception of data to the terminal device referenced by fildes. depending upon the value of action as follows:
TCOOFF
Suspend output.
TCOON
Restart suspended output.
TCIOFF
Transmit a STOP character, to cause the terminal to stop transmitting data to the system.
TCION
Transmit a START character, to cause the terminal to start transmitting data to the system.
The action constants are defined in <termios.h>.
Tcflush discards (flushes) data associated with the terminal device referred to by fildes. The data may be written but not transmitted or received but not read. The method used depends upon the value of queue_selector:
TCIFLUSH
Data received, but not read is flushed.
TCOFLUSH
Data written, but not transmitted is flushed.
TCIOFLUSH
Data received, but not read, and data written, but not transmitted is flushed.
The queue_selector constants are defined in <termios.h>.
Tcsendbreak causes the transmission of a continuous stream of zero-valued bits (break) for a specified duration when using asynchronous serial data transmission on the terminal device referred to by fildes. For CX/UX, the value of duration should always be zero, because the system only supports transmission of a continuous stream of zero bits for 0.25 second. All other values of duration will be ignored and only transmit for 0.25 second.
SEE ALSO
DIAGNOSTICS
Upon successful completion, a value of zero is returned by all functions. If not, a value of -1 is returned and errno is set.
Errno is set to one of the following values for tcdrain:
[EBADF]
Fildes is not a valid open file descriptor.
[EINTR] A signal interrupted the function.
Errno is set to one of the following values for tcflow:
[EBADF]
Fildes is not a valid open file descriptor.
[EINVAL] The action argument is not a proper value as defined in <termios.h>.
[ENOTTY] Fildes is not associated with a terminal device.
Errno is set to one of the following values for tcflush:
[EBADF]
Fildes is not a valid open file descriptor.
[EINVAL] The queue_selector argument is not a proper value as defined in <termios.h>.
[ENOTTY] Fildes is not associated with a terminal device.
Errno is set to one of the following values for tcsendbreak:
[EBADF]
Fildes is not a valid open file descriptor.
[ENOTTY] Fildes is not associated with a terminal device.